胎心监测是评估胎儿宫内状况的重要措施,通过胎心监测获得的信息有助于及早发现胎儿宫内缺氧并及时干预,但随着胎儿监护技术的广泛使用和种类多样化,过度监护导致过度干预等问题日渐显露。本文对不同类型的胎心监测方法及其临床价值进行讨论。

Fetal heart rate (FHR) monitoring is an important tool to assess fetal intrauterine condition. The information obtained from fetal heart rate monitoring is helpful for timely detection of fetal intrauterine hypoxia and early intervention. But excessive intervention in the process of labor is increasingly with the widespread application and the diversification of fetal monitoring techniques. In this article, we will discuss different types of fetal heart rate monitoring methods and their clinical value.

[1]
Ayres-De-Campos D, Spong CY, Chandraharan E, et al. FIGO consensus guidelines on intrapartum fetal monitoring: Cardiotocography [J]. Int J Gynaecol Obstet, 2015, 131(1):13-24.
[2]
Bishop, Edward H. Fetal acceleration test[J]. Am J Obstet Gynecol, 1981, 141(8):905-909.
[3]
Lavin JP, Miodovnik M, Barden TP. Relationship of NST reactivity and gestational age[J]. Obstetrics and Gynecology, 1984, 63(3): 338-344.
[4]
Goodlin R C. Intrapartum electronic fetal heart rate monitoring versus intermittent auscultation: A meta-analysis[J]. Obstet Gynecol, 1995, 85(4):643:643-644.
[5]
Alfirevic Zarko, Devane Declan, Gyte Gillian ML. Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour [J]. Cochrane Database Syst Rev, 2013, 31(5): CD006066.
[6]
Caughey AB, Cahill AG, Guise JM, et al. Safe prevention of the primary cesarean delivery[J]. Am J Obstet Gynecol, 2014, 210(3): 179-193.
[7]
Committee on Obstetric Practice. Committee Opinion No. 687: Approaches to Limit Intervention During Labor and Birth[J]. Obstet Gynecol, 2017, 129(2): e20-e28.
[8]
田宁,陈奕,范玲,等. 胎儿Holter监测及胎心率量化参数在产程中的应用[J]. 中华围产医学杂志,2016, 19(9): 695-699.
[9]
Özge Tunçalp, Moran AC, Bucagu M, et al. Developing measures for WHO recommendations on antenatal care for a positive pregnancy experience: a conceptual framework and scoping review[J]. BMJ Open, 2019, 9(4): e024130.
[10]
Bohren MA, Hofmeyr GJ, Sakala C, et al. Continuous support for women during childbirth[J]. Cochrane Database Syst Rev, 2017, 7(2): CD003766.
[11]
Alfirevic Z, Devane D, Gyte GM, et al. Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour[J]. Cochrane Database Syst Rev, 2017, 7(2): CD006066.
[12]
Richard B. Cerebral palsy[J]. Lancet, 2018, 392(10147): 545.
[13]
Ellenberg JH, Nelson KB. The association of cerebral palsy with birth asphyxia: a definitional quagmire[J]. Dev Med Child Neurol, 2012, 55(3): 210-216.
[14]
Grimes DA, Peipert JF. Electronic fetal monitoring as a public health screening program: the arithmetic of failure[J]. Obstet Gynecol, 2010, 116(6): 1397-400.
[15]
Bakker JJ, Janssen PF, van Halem K, et al. Internal versus external tocodynamometry during induced or augmented labour[J]. Cochrane Database of Systematic Reviews, 2013, (8): CD006947.
[16]
Delgado Nunes V, Gholitabar M, Sims JM, et al. Intrapartum care of healthy women and their babies: summary of updated NICE guidance[J]. BMJ, 2014, 349(dec03 6): g6886-g6886.
[17]
中华医学会围产医学分会. 电子胎心监护应用专家共识[J]. 中华围产医学杂志,2015, 18(7): 486-490.
[18]
ACOG Practice Bulletin No. 205: Vaginal Birth After Cesarean Delivery [J]. Obstet Gynecol, 2019, 133: e110-e127.
[19]
Mugyenyi GR, Atukunda EC, Ngonzi J, et al. Functionality and acceptability of a wireless fetal heart rate monitoring device in term pregnant women in rural Southwestern Uganda[J]. BMC Pregnancy Childbirth, 2017, 17(1):178.
[20]
Skupski DW, Rosenberg CR, Eglinton GS. Intrapartum fetal stimulation tests: a meta-analysis[J]. Obstet Gynecol, 2002, 99(1):129-134.
[21]
Liston R, Sawchuck D, Young D, et al. Fetal Health Surveillance: Antepartum and Intrapartum Consensus Guideline[J]. J Obstet Gynaecol Can, 2007, 29(9): S3-S4.
[22]
李博雅,杨慧霞. 胎儿监测方法及评价[J]. 中华围产医学杂志,2016, 19(6): 442-445.
[23]
Belfort MA, Saade GR, Thom E, et al. A Randomized Trial of Intrapartum Fetal ECG ST-Segment Analysis[J]. N Engl J Med, 2015, 373(7):632-641.
[1] 王天成, 杜妍妍, 陈娟, 孙道霞, 乐菁华, 薛卫娟. 电子胎心监护正弦波型12例临床分析[J]. 中华妇幼临床医学杂志(电子版), 2010, 06(06): 437-439.
[2] 周翠香, 郭晓辉. 妊娠合并糖尿病患者胎儿宫内安全监测[J]. 中华产科急救电子杂志, 2021, 10(01): 25-30.
[3] 白宇翔, 漆洪波. 电子胎心监护的应用及研究进展[J]. 中华产科急救电子杂志, 2020, 09(03): 150-153.
阅读次数
全文


摘要