[1] |
Young RC.Myocytes,myometrium,and uterine contractions[J].Ann N Y Acad Sci,2007,1101:72-84.
|
[2] |
Rabotti C,Sammali F,Kuijsters N,et al.Analysis of uterine activity in nonpregnant women by electrohysterography: a feasibility study[J].Annu Int Conf IEEE Eng Med Biol Soc,2015,2015:5916-5919.
|
[3] |
Haran G,Elbaz M,Fejgin MD,et al.A comparison of surface acquired uterine electromyography and intrauterine pressure catheter to assess uterine activity[J].Am J Obstet Gynecol,2012,206(5):412.e1-412.e5.
|
[4] |
Arrabal PP, Nagey DA. Is manual palpation of uterine contractions accurate?[J].Am J Obstet Gynecol,1996,174(1 Pt 1):217-219.
|
[5] |
Rosen H,Yogev Y.Assessment of uterine contractions in labor and delivery[J].Am J Obstet Gynecol,2023,228(5S):S1209-1221.
|
[6] |
白宇翔,漆洪波.电子胎心监护的应用及研究进展[J/CD].中华产科急救电子杂志,2020,9(3):150-153.
|
[7] |
Ayres-de-Campos D,Nogueira-Reis Z.Technical characteristics of current cardiotocographic monitors[J].Best Pract Res Clin Obstet Gynaecol,2016,30:22-32.
|
[8] |
Ayres-de-Campos D,Spong CY,Chandraharan E,et al.FIGO consensus guidelines on intrapartum fetal monitoring:cardiotocography[J].Int JGynaecol Obstet,2015,131(1):13-24.
|
[9] |
Steer PJ.Standards in fetal monitoring--practical requirements for uterine activity measurement and recording[J].Br J Obstet Gynaecol,1993,100 Suppl 9:32-36.
|
[10] |
Miles AM,Monga M,Richeson KS.Correlation of external and internal monitoring of uterine activity in a cohort of term patients[J].Am J Perinatol,2001,18(3):137-140.
|
[11] |
中华医学会妇产科学分会产科学组.孕前和孕期保健指南(2018)[J].中华妇产科杂志,2018,53(1):7-13.
|
[12] |
Sammali F,Blank C,Bakkes TGH,et al.Multi-modal uterineactivity measurements for prediction of embryo implantation by machine learning[J].IEEE Access,2021,9:47096-47111.
|
[13] |
Beard RW,Nathanielsz PW.Fetal physiology and medicine:the basis of perinatology[M]. 2nd ed.Oxford:Butterworth-Heinemann,1984:679-711.
|
[14] |
Dowdle MA.Comparison of two intrauterine pressure catheters during labor[J].JReprod Med,2003,48(7):501-505.
|
[15] |
Miller FC,Yeh SY,Schifrin BS,et al.Quantitation of uterine activity in 100 primiparous patients[J].Am J Obstet Gynecol,1976,124(4):398-405.
|
[16] |
谢幸,孔北华,段涛.妇产科学[M].9版.北京:人民卫生出版社,2018:183.
|
[17] |
Hautakangas T,Uotila J,Kontiainen J,et al.Impact of obesity on uterine contractile activity during labour:a blinded analysis of a randomised controlled trial cohort[J].BJOG,2022,129(10):1790-1797.
|
[18] |
The American College of Obstetricians and Gynecologists.ACOG practice bulletin No.107:induction of labor[J].Obstet Gynecol,2009,114(2 Pt 1):386-397.
|
[19] |
Bakker JJ,Janssen PF,van Halem K,et al.Internal versus external tocodynamometry during induced or augmented labour[J].Cochrane Database Syst Rev,2013(8):CD006947.
|
[20] |
Trudinger BJ,Pryse-Davies J.Fetal hazards of the intrauterine pressure catheter:five case reports[J].Br J Obstet Gynaecol,1978,85(8):567-572.
|
[21] |
Wilmink FA,Wilms FF,Heydanus R,et al.Fetal complications after placement of an intrauterine pressure catheter:a report of two cases and review of the literature[J].J Matern Fetal Neonatal Med,2008,21(12):880-883.
|
[22] |
Lind BK.Complications caused by extramembranous placement of intrauterine pressure catheters[J].Am J Obstet Gynecol,1999,180(4):1034-1035.
|
[23] |
Nuttall ID.Perforation of a placental fetal vessel by an intrauterine pressure catheter[J].Br J Obstet Gynaecol,1978,85(8):573-574.
|
[24] |
Rood KM.Complications associated with insertion of intrauterine pressure catheters:an unusual case of uterine hypertonicity and uterine perforation resulting in fetal distress after insertion of an intrauterine pressure catheter[J].Case Rep Obstet Gynecol,2012,2012:517461.
|
[25] |
Harper LM,Shanks AL,Tuuli MG,et al.The risks and benefits of internal monitors in laboring patients[J].Am J Obstet Gynecol,2013,209(1):38.e1-38.e6.
|
[26] |
Cabrera IB,Quiñones JN,Durie D,et al.Use of intracervical balloons and chorioamnionitis in term premature rupture of membranes[J].JMatern Fetal Neonatal Med,2016,29(6):967-971.
|
[27] |
Gee SE,Ma'ayeh M,Ward C,et al.Intrauterine pressure catheter use is associated with an increased risk of postcesarean surgical site infections[J].Am J Perinatol,2020,37(6):557-561.
|
[28] |
Harbison L,Bell L.Anaphylactoid syndrome after intrauterine pressure catheter placement[J].Obstet Gynecol,2010,115(2 Pt 2):407-408.
|
[29] |
Matsuo K,Lynch MA,Kopelman JN,et al.Anaphylactoid syndrome of pregnancy immediately after intrauterine pressure catheter placement[J].Am JObstet Gynecol,2008,198(2):e8-9.
|
[30] |
Mirza FG, Thaker HM, Flejter WL, et al. Fetomaternal hemorrhage following placement of an intrauterine pressure catheter:report of a new association[J].Case Rep Obstet Gynecol,2015,2015:348279.
|
[31] |
Trommelen LM,Reynaers E,Mol B,et al.A case of perinatal death after insertion of an intrauterine pressure catheter[J].Eur J Obstet Gynecol Reprod Biol,2021,265:217-219.
|
[32] |
Hofmeyr GJ,Lawrie TA.Amnioinfusion for potential or suspected umbilical cord compression in labour[J].Cochrane Database Syst Rev,2012,1(1):CD000013.
|
[33] |
Lumsden MA,Baird DT.Intra-uterine pressure in dysmenorrhea[J].Acta Obstet Gynecol Scand,1985,64(2):183-186.
|
[34] |
Strauss JF, Barbieri RL. Yen & Jaffe's reproductive endocrinology: physiology, pathophysiology, and clinical management[M].8th ed.Philadelphia:Elsevier,2019:916-961.e5.
|
[35] |
Bulletti C,de Ziegler D,Polli V,et al.Uterine contractility during the menstrual cycle[J].Hum Reprod,2000,15 Suppl 1:81-89.
|
[36] |
Steer CM,Hertsch GJ.Electrical activity of the human uterus in labor;the electrohysterograph[J].Am JObstet Gynecol,1950,59(1):25-40.
|
[37] |
Devedeux D, Marque C, Mansour S, et al. Uterine electromyography:a critical review[J].Am J Obstet Gynecol,1993,169(6):1636-1653.
|
[38] |
Hao D,Qiu Q,Zhou X,et al.Application of decision tree in determining the importance of surface electrohysterography signal characteristics for recognizing uterine contractions[J].Biocybern Biomed Eng,2019,39(3):806-813.
|
[39] |
Vinken MP,Rabotti C,Mischi M,et al.Accuracy of frequencyrelated parameters of the electrohysterogram for predicting preterm delivery:a review of the literature[J].Obstet Gynecol Surv,2009,64(8):529-541.
|
[40] |
Benfield R,Newton ER.Use of external uterine electromyography across stage I labor[J].J Midwifery Womens Health,2023,68(5):575-580.
|
[41] |
Thijssen K,Tissink J,Dieleman JP,et al.Qualitative assessment of interpretability and observer agreement of three uterine monitoring techniques[J].Eur J Obstet Gynecol Reprod Biol,2020,255:142-146.
|
[42] |
许琦,王楠,邢丽莉,等.腹电式动态胎儿监护仪的临床应用研究[J].中国妇产科临床杂志,2023,24(6):605-608.
|
[43] |
Euliano TY,Nguyen MT,Darmanjian S,et al.Monitoringuterine activity during labor:a comparison of 3 methods[J].Am JObstet Gynecol,2013,208(1):66.e1-66.e6.
|
[44] |
Iams JD.Prediction and early detection of preterm labor[J].Obstet Gynecol,2003,101(2):402-412.
|
[45] |
玛丽帕提·马尔旦,时春艳.早产预测的研究现状[J/CD].中华产科急救电子杂志,2018,7(4):208-211.
|
[46] |
Leitich H,Egarter C,Kaider A,et al.Cervicovaginal fetal fibronectin as a marker for preterm delivery:a meta-analysis[J].Am J Obstet Gynecol,1999,180(5):1169-1176.
|
[47] |
Peaceman AM,Andrews WW,Thorp JM,et al.Fetal fibronectin as a predictor of preterm birth in patients with symptoms:a multicenter trial[J].Am JObstet Gynecol,1997,177(1):13-18.
|
[48] |
Gudicha DW, Romero R, Kabiri D, et al. Personalized assessment of cervical length improves prediction of spontaneous preterm birth:a standard and a percentile calculator[J].Am J Obstet Gynecol,2021,224(3):288.e1-288.e17.
|
[49] |
Lucovnik M,Kuon RJ,Chambliss LR,et al.Use of uterine electromyography to diagnose term and preterm labor[J].Acta Obstet Gynecol Scand,2011,90(2):150-157.
|
[50] |
Garfield RE,Maner WL.Physiology and electrical activity of uterine contractions[J].Semin Cell Dev Biol,2007,18(3):289-295.
|
[51] |
Russo S,Batista A,Esgalhado F,et al.Alvarez waves in pregnancy:a comprehensive review[J].Biophys Rev,2021,13(4):563-574.
|
[52] |
Mas-Cabo J, Prats-Boluda G, Garcia-Casado J, et al.Electrohysterogram for ANN-based prediction of imminent labor in women with threatened preterm labor undergoing tocolytic therapy[J].Sensors(Basel),2020,20(9):2681.
|
[53] |
Sadi-Ahmed N,Kacha B,Taleb H,et al.Relevant features selection for automatic prediction of preterm deliveries from pregnancy electrohysterograhic(EHG)records[J].J Med Syst,2017,41(12):204.
|
[54] |
Lucovnik M,Maner WL,Chambliss LR,et al.Noninvasive uterine electromyography for prediction of preterm delivery[J].Am JObstet Gynecol,2011,204(3):228.e1-228.e10.
|
[55] |
Peng J,Hao D,Yang L,et al.Evaluation of electrohysterogram measured from different gestational weeks for recognizing preterm delivery:a preliminary study using random forest[J].Biocybern Biomed Eng,2020,40(1):352-362.
|
[56] |
Marinescu PS,Young RC,Miller LA,et al.Mid-trimester uterine electromyography in patients with a short cervix[J].Am JObstet Gynecol,2022,227(1):83.e1-83.e17.
|
[57] |
Yuan W,López Bernal A.Cyclic AMP signalling pathways in the regulation of uterine relaxation[J].BMC Pregnancy Childbirth,2007,7 Suppl 1(Suppl 1):S10.
|
[58] |
Garfield RE,Saade G,Buhimschi C,et al.Control and assessment of the uterus and cervix during pregnancy and labour[J].Hum Reprod Update,1998,4(5):673-695.
|
[59] |
Maner WL,Garfield RE,Maul H,et al.Predicting term and preterm delivery with transabdominal uterine electromyography[J].Obstet Gynecol,2003,101(6):1254-1260.
|
[60] |
Degbedzui DK,Yüksel ME.Accurate diagnosis of term-preterm births by spectral analysis of electrohysterography signals[J].Comput Biol Med,2020,119:103677.
|
[61] |
Lucovnik M,Novak-Antolic Z,Garfield RE.Use of non-invasive uterine electromyography in the diagnosis of preterm labour[J].Facts Views Vis Obgyn,2012,4(1):66-72.
|
[62] |
Kandil MA, Abdel-Sattar MM, Abdel-Salam SM, et al.Abdominal electromyography may predict the response to tocolysis in preterm labor[J].Eur J Obstet Gynecol Reprod Biol,2012,160(1):18-21.
|
[63] |
Hadar E,Melamed N,Aviram A,et al.Effect of an oxytocin receptor antagonist(atosiban)on uterine electrical activity[J].Am J Obstet Gynecol,2013,209(4):384.e1-384.e7.
|
[64] |
Mas-Cabo J,Prats-Boluda G,Ye-Lin Y,et al.Characterization of the effects of atosiban on uterine electromyograms recorded in women with threatened preterm labor[J].Biomed Signal Proces,2019,52:198-205.
|
[65] |
董欣,李雪兰.产后出血的早期识别及诊断[J/OL].中华产科急救电子杂志,2022,11(3):144-147.
|
[66] |
Diaz-Martinez A,Mas-Cabo J, Prats-Boluda G, et al. A comparative study of vaginal labor and caesarean section postpartum uterine myoelectrical activity[J].Sensors(Basel),2020,20(11):3023.
|
[67] |
Fanchin R,Ayoubi JM.Uterine dynamics:impact on the human reproduction process[J].Reprod Biomed Online,2009,18 Suppl 2:57-62.
|
[68] |
Sammali F,Kuijsters N,Schoot BC,et al.Feasibility of transabdominal electrohysterography for analysis of uterine activity in nonpregnant women[J].Reprod Sci,2018,25(7):1124-1133.
|
[69] |
Georgiou J,Lekkas K,Varnava G,et al.The electrouterograph:a novel tool for assessing uterine contractions of non-pregnant women[J].IEEE Open JEng Med Biol,2022,3:34-40.
|