Home    中文  
 
  • Search
  • lucene Search
  • Citation
  • Fig/Tab
  • Adv Search
Just Accepted  |  Current Issue  |  Archive  |  Featured Articles  |  Most Read  |  Most Download  |  Most Cited

Chinese Journal of Obstetric Emergency(Electronic Edition) ›› 2014, Vol. 03 ›› Issue (04): 280-283. doi: 10.3877/cma.j.issn.2095-3259.2014.04.014

Special Issue:

• Original Article • Previous Articles     Next Articles

Clinical analysis of neonatal umbilical artery blood gas analysis at delivery: 320 cases

Yiheng Liang1, Ping Liu1, Yun Li1, Shangrong Fan1,()   

  1. 1. Department of Gynecology and Obstetrics, Peking University Shenzhen hospital, Shenzhen 518036, China
  • Received:2014-09-03 Online:2014-11-18 Published:2014-11-18
  • Contact: Shangrong Fan
  • About author:
    Corresponding author: Fan Shangrong, Email:

Abstract:

Objective

To investigate the clinical application value of neonatal umbilical artery blood gas analysis.

Methods

The umbilical artery blood samples of 320 newborns, who were born in Peking University Shenzhen hospital, were obtained from October 23rd 2013 to May 13rd 2014. The relations between umbilical artery blood gas analysis with Apgar score, character of amniotic fluid and newborn outcome were analyzed.

Results

(1)The level of pH value, PaCO2, PaO2, HCO3-, and base excess(BE) value in Apgar score of 4 to 7 at 1 min group were (7.15±0.11)、(64.21±21.62)mmHg, (9.21±4.69)mmHg, (21.12±6.98)mmol/L, (-9.06±7.07)mmol/L; and the datum in Apgar score ≥8 at 1 min group were (7.28±0.10), (43.16±15.06)mmHg, (20.38±9.21)mmHg, (19.59±5.31)mmol/L, (-6.79±4.92)mmol/L, respectively. There were significant differences of pH value, PaO2 and PaCO2 between the two groups; t=2.914, -2.764, 2.501, all P value <0.05. (2) The level of pH value, PaCO2, PaO2, HCO3-, BE value in normal amniotic fluid group were (7.29±0.10), (43.64±15.35)mmHg, (20.40±7.85)mmHg, (19.81±5.28)mmol/L, (-6.59±4.85)mmol/L; In meconium-staining amniotic fluid Ⅰ group, the datum were (7.29±0.06), (43.88±15.79)mmHg, (21.41±9.61)mmHg, (20.20±6.92)mmol/L, (-6.24±5.55)mmol/L, respectively; In meconium-staining amniotic fluid Ⅱ group, the datum were (7.24±0.14), (40.36±14.70)mmHg, (17.38±4.75)mmHg, (16.55±4.13)mmol/L, (-10.09±4.98)mmol/L, respectively. There were no significant differences of the indicators in the three groups.

Conclusions

Umbilical artery blood gas analysis is the objective indicator to diagnose neonatal asphyxia. Meconium-staining amniotic fluid Ⅰ and Ⅱ are not the indicators to diagnose fetal distress.

Key words: Blood gas analysis, Apgar score, Asphyxia neonatorum, Acidosis, Umbilical arteries, Amniotic fluid

京ICP 备07035254号-20
Copyright © Chinese Journal of Obstetric Emergency(Electronic Edition), All Rights Reserved.
Tel: 020-81256537 E-mail: chankejijiuzazhi@163.com
Powered by Beijing Magtech Co. Ltd